Table 1. Cab Troubleshooting Procedures - Continued.
0022
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Blower Motor Does NOT
1. If 24 Volts is found, proceed to
Function in One or More
0296), measure for voltage
step 25.
Speeds - Continued
between pin 5 on instrument
2. If voltage is NOT found, proceed
panel harness connector E-C14
to step 21.
on instrument panel harness con-
166).
21. Turn ignition switch and battery
disconnect switch to OFF position
(TM 5-2410-241-10).
1. If continuity is found, proceed to
0296), test for continuity between
step 23.
pin 2 on instrument panel harness
connector E-C14 (WP 0018, Fig-
platform harness (WP 0209) and
ure 166) and ground
instrument panel harness (WP
0260). Ensure all harness con-
nectors are reconnected. Verify
correct operation of machine (TM
5-2410-241-10).
23. Disconnect instrument panel har-
ness blower motor speed switch
171) from blower motor speed
switch.
1. If continuity is found, proceed to
0296), test for continuity between
step 25.
pin 3 on instrument panel harness
blower motor speed switch con-
instrument panel harness (WP
0260). Ensure all harness con-
171) and pin 5 on instrument
nectors are reconnected. Verify
panel harness connector E-C14
correct operation of machine (TM
5-2410-241-10).
25. Turn ignition switch and battery
disconnect switch to OFF position
(TM 5-2410-241-10).
26. Remove blower motor (WP 0227).
27. Disconnect blower motor harness
resistor connector EE-C3 (WP
0018, Figure 174) from blower
motor resistor.
0022-124