TM 5-2410-241-23-1
0022
Table 1. Cab Troubleshooting Procedures - Continued.
0022
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Blower Motor Does NOT
1.
If continuity is found, replace
Function in One or More
blower motor resistor (WP 0219).
Speeds - Continued
terminal 1 on blower motor har-
Ensure all harness connectors
ness resistor connector EE-C3
are reconnected. Verify correct
operation of machine (TM 5-2410-
on blower motor harness connec-
241-10).
blower motor harness (WP 0219).
Ensure all harness connectors
are reconnected. Verify correct
operation of machine (TM 5-2410-
241-10).
44. Turn ignition switch and battery
disconnect switch to OFF position
(TM 5-2410-241-10).
45. Disconnect instrument panel har-
Figure 166) from blower motor
harness connector EE-C8 (WP
46. Turn battery disconnect switch
and ignition switch to ON position
(TM 5-2410-241-10).
47. Turn blower motor switch to MED
(SPEED 2) (TM 5-2410-241-10).
1. If 24 Volts is found, proceed to
0296), measure for voltage
step 52.
between pin 4 on instrument
2. If voltage is NOT found, proceed
panel harness connector E-C14
to step 49.
on instrument panel harness con-
166).
49. Turn ignition switch and battery
disconnect switch to OFF position
(TM 5-2410-241-10).
50. Disconnect instrument panel har-
Figure 171) from blower motor
speed switch.
0022-127