Table 1. Cab Troubleshooting Procedures - Continued.
0022
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Blower Motor Does NOT
1.
If continuity is found, replace
Function in One or More
blower motor resistor (WP 0219).
Speeds - Continued
pin C on blower motor harness
Ensure all harness connectors
are reconnected. Verify correct
ure 174) and pin 1 on blower
operation of machine (TM 5-2410-
motor harness connector EE-C8
241-10).
2.
blower motor harness (WP 0219).
Ensure all harness connectors
are reconnected. Verify correct
operation of machine (TM 5-2410-
241-10).
68. Turn ignition switch and battery
disconnect switch to OFF position
(TM 5-2410-241-10).
69. Disconnect instrument panel har-
Figure 166) from blower motor
harness connector EE-C8 (WP
70. Turn battery disconnect switch
and ignition switch to ON position
(TM 5-2410-241-10).
71. Turn blower motor switch to MAX
(SPEED 4) (TM 5-2410-241-10).
1. If 24 Volts is found, proceed to
0296), measure for voltage
step 76.
between pin 3 on instrument
2. If voltage is NOT found, proceed
panel harness connector E-C14
to step 73.
on instrument panel harness con-
166).
73. Turn ignition switch and battery
disconnect switch to OFF position
(TM 5-2410-241-10).
74. Disconnect instrument panel har-
ness blower motor speed switch
171) from blower motor speed
switch.