Table 1. Cab Troubleshooting Procedures - Continued.
0022
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
No Power with Ignition
8. Remove Fuse #14 (Figure 15,
Switch ON - Continued
Item 1) from fuse panel (TM 5-
2410-241-10).
Figure 15. Fuse #14.
0022
9. Using digital multimeter (WP
1. If continuity is found, install Fuse
0296), test for continuity between
#14 on fuse panel (TM 5-2410-
blades of Fuse #14.
241-10). Proceed to step 10.
2. If continuity is NOT found, replace
Fuse #14 (TM 5-2410-241-10).
Proceed to step 14.
10. Turn battery disconnect switch
and ignition switch to ON position
(TM 5-2410-241-10).
11. Turn ignition switch and battery
disconnect switch to OFF position
(TM 5-2410-241-10).
12. Remove Fuse #14 (Figure 15,
Item 1) from fuse panel (TM 5-
2410-241-10).
0022-133