TM 5-2410-241-23-1
0022
Table 1. Cab Troubleshooting Procedures - Continued.
0022
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Blower Motor Does NOT
1. If 24 Volts is found, proceed to
Function in One or More
0296), measure for voltage
step 40.
Speeds - Continued
between pin 5 on instrument
2. If voltage is NOT found, proceed
panel harness connector E-C14
to step 37.
on instrument panel harness con-
166).
37. Turn ignition switch and battery
disconnect switch to OFF position
(TM 5-2410-241-10).
38. Disconnect instrument panel har-
ness blower motor speed switch
171) from blower motor speed
switch.
1. If continuity is found, replace
blower motor switch (WP 0262).
pin 3 on instrument panel harness
Ensure all harness connectors
blower motor speed switch con-
are reconnected. Verify correct
operation of machine (TM 5-2410-
171) and pin 5 on instrument
241-10).
panel harness connector E-C14
instrument panel harness (WP
0260). Ensure all harness con-
nectors are reconnected. Verify
correct operation of machine (TM
5-2410-241-10).
40. Turn ignition switch and battery
disconnect switch to OFF position
(TM 5-2410-241-10).
41. Remove blower motor (WP 0227).
42. Disconnect blower motor harness
resistor connector EE-C3 (WP
0018, Figure 174) from blower
motor resistor.
0022-126