TM 5-2410-241-23-1
0026
COOLING SYSTEM INSPECTION CONTINUED
00026
29. Inspect water valve (Figure 9, Item 8) for Class III leaks and damage.
a. If leak is at clamps (Figure 9, Item 9) tighten clamps.
b. If water valve (Figure 9, Item 8) is leaking or damaged, replace water valve (WP 0244).
c.
If water valve (Figure 9, Item 8) is OK, proceed to step 30.
30. Inspect three heater lines (Figure 9, Items 10 and 14), and two clamps (Figure 7, Item 9 and Item 13) for
Class III leaks and damage.
a. If leak is at clamps (Figure 9, Item 9 and item 13), tighten clamps.
b. If heater lines (Figure 9, Items 10 and 14) are leaking or damaged, replace heater lines (WP 0243).
c.
If two heater lines (Figure 9, Items 10 and 14), and two clamps (Figure 9, Items 9 and 13) are OK, proceed
to step 31.
Figure 9. Heater Control Valve.
0026
0026-12