TM 5-2410-241-23-1
0026
COOLING SYSTEM INSPECTION CONTINUED
00026
15. Inspect aftercooler outlet hose (Figure 6, Item 2) and two clamps (Figure 6, Item 1) for Class III leaks and dam-
age.
a. If leak is at clamps (Figure 6, Item 1), tighten clamps.
b. If aftercooler outlet hose (Figure 6, Item 2) is leaking or damaged, replace aftercooler outlet hose, refer to
water temperature regulator outlet hose (WP 0049).
c.
If aftercooler outlet hose (Figure 6, Item 2) and two clamps (Figure 6, Item 1) are OK, proceed to step 16.
16. Inspect upper water temperature regulator outlet hose (Figure 6, Item 3) and two clamps (Figure 6, Item 4) for
Class III leaks and damage.
a. If leak is at clamps (Figure 6, Item 4), tighten clamps.
b. If upper water temperature regulator outlet hose (Figure 6, Item 3) is leaking or damaged, replace after-
cooler outlet hose, refer to water temperature regulator outlet hose (WP 0049).
c.
If upper water temperature regulator outlet hose (Figure 6, Item 3) and two clamps (Figure 6, Item 4) are
OK, proceed to step 17.
Figure 6. Right Side Hoses.
0026