• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
Figure 1. Coolant Tank and Hoses.
Figure 3. Radiator.

Field Maintenance Manual 1 D7R Dozer Type I With Winch and Type II With Ripper
Page Navigation
  906    907    908    909    910  911  912    913    914    915    916  
img
. . .
TM 5-2410-241-23-1
0026
COOLING SYSTEM INSPECTION CONTINUED
4. Visually inspect coolant tank (Figure 2, Item 1), sight glass (Figure 2, Item 2), vent line (Figure 2, Item 3) and
two clamps (Figure 2, Item 4) for Class III leaks and damage.
a. If leak is at clamps (Figure 2, Item 4), tighten clamp.
b. If vent line (Figure 2, Item 3) is leaking or damaged replace vent line (WP 0049).
c.
If upper coolant tank (Figure 2, Item 1) or sight glass (Figure 2, Item 2) is leaking or damaged replace cool-
ant tank (WP 0043).
d. If coolant tank (Figure 2, Item 1), sight glass (Figure 2, Item 2), vent line (Figure 2, Item 3) and two clamps
(Figure 2, Item 4) are OK, proceed to step 5.
Figure 2. Coolant Tank and Hoses.
0026
0026-3


Privacy Statement