14
TM 5-2410-241-23-1
FIELD MAINTENANCE
-
UPPER COOLANT TANK REPLACEMENT
0
043
Removal, Cleaning and Inspection, Installation
INITIAL SETUP
References
Tools and Special Tools
0
0
Tool Kit, General Mechanic's
WP 0295
0
(WP 0302, Item 65)
0
Equipment Condition
0
Wrench Combination 1-1/2" (S0793)
Machine parked (TM 5-2410-241-10)
(WP 0302, Item 68)
0
0
Coolant drained (WP 0113)
0
Materials/Parts
0
0
Rag, Wiping (WP 0303, Item 24)
Hood removed (WP 0200)
0
0
Tag, Marker (WP 0303, Item 34)
0
Drawing Required
O-ring (6)
0
0
TM 5-2410241-24P, Figure 5
0
Personnel Required
0
Estimated Time to Complete
Two
0
0
5.0 Hr
0
REMOVAL
00043
WARN I N G
Components with metal parts can cause severe burns at operating temperature. Allow
components to cool before performing maintenance on them. Wear insulated gloves, long
sleeves, and eye protection when working with heated parts. Failure to follow this warning
may cause injury or death to personnel.
1. Remove three bolts (Figure 1, Item 2), washers (Figure 1, Item 1), and cover (Figure 1, Item 3) from radiator
guard (Figure 1, Item 4).
Figure 1. Upper Cover.
0043