Figure 1. Ammeter.
Figure 3. Alternator.

Field Maintenance Manual 1 D7R Dozer Type I With Winch and Type II With Ripper
Page Navigation
  934    935    936    937    938  939  940    941    942    943    944  
img
.
TM 5-2410-241-23-1
0028
4. Connect clamp (Figure 2, Item 4) of ammeter (Figure 2, Item 1) around positive alternator cable (Figure 2,
Item 2) connected to alternator (Figure 2, Item 3) with the arrow (Figure 2, Item 5) of the ammeter facing the
direction of current flow (towards the alternator).
5. Start the engine (TM 5-2410-241-10), and fully depress and hold throttle pedal.
6. Operate engine with throttle fully depressed while an assistant monitors ammeter.
a. If initial charging current is greater than 70 amps, proceed to step 7.
b. If initial charging current is less than 70 amps, alternator is faulty. Replace alternator (WP 0099).