• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
Figure 2. Equalizer Bar Oil Levels.
Figure 3. Final Drive Oil Level.

Field Maintenance Manual 1 D7R Dozer Type I With Winch and Type II With Ripper
Page Navigation
  1023    1024    1025    1026    1027  1028  1029    1030    1031    1032    1033  
img
TM 5-2410-241-23-1
0039
Table 1. Preventive Maintenance Checks and Services (PMCS) - Continued.
LOCATION
ITEM TO
CHECK/
ITEM
NOT FULLY MISSION
SERVICE
NO.
INTERVAL
PROCEDURE
CAPABLE IF:
4
250 Hours
Final Drive Oil
WARN I N G
or Monthly
Level -Check
Contact with oil can damage skin. Wear gloves when handling
engine oil. If oil contacts skin, wash it off immediately.
Lubricating oil is very slippey. Immediately wipe up any spills.
r
Failure to follow these warnings may cause injury or death to per-
sonnel.
a. Position one final drive so oil level
Final drive oil level low.
mark (Figure 3, Item 1) is horizontal
and drain plug (Figure 2, Item 3) is at
bottom.
b. Remove oil filler plug (Figure 2,
Item 2) and O-ring.
c. The oil level should be at bottom of
the filler plug opening. Refer to LO 5-
2410-241-13 for correct amount and
type of final drive oil. If necessary, add
oil.
d. Clean oil fill plug with clean rag.
Inspect O-ring. If O-ring is not
damaged it may be reused until oil
change.
e. Install oil filler plug (Figure 3, Item
2) and O-ring.
f. Repeat steps to check oil level on
other final drive.
0039-6