9. Remove plug (Figure 5, Item 7) from pipe (Figure 5, Item 1).
10. Remove bolt (Figure 5, Item 5), washer (Figure 5, Item 6), and clamp (Figure 5, Item 4) from engine (Figure 5,
Item 8).
11. Remove four bolts (Figure 5, Item 3), washers (Figure 5, Item 2), and pipe (Figure 5, Item 1) from engine
(Figure 5, Item 8).
12. Remove O-ring (Figure 5, Item 9) from pipe (Figure 5, Item 1). Discard O-ring.
Figure 5. Upper Cooling Pipe.
0049
END OF TASK
CLEANING AND INSPECTION
00049
Clean and inspect all parts IAW Mechanical General Maintenance Instructions (WP 0295).
END OF TASK