TM 5-2410-241-23-2
0071
FILTER BASE AND MOUNTING PLATE REMOVAL CONTINUED
N OT E
Cap and plug all lines, hoses and tubes to prevent contamination and leaks.
7. Loosen tube nut (Figure 7, Item 13) and remove hose (Figure 7, Item 12) from fitting (Figure 7, Item 14).
Position hose aside.
8. Remove fitting (Figure 7, Item 14) from filter base (Figure 7, Item 1).
9. Remove two O-rings (Figure 7, Item 15) from fitting (Figure 7, Item 14). Discard O-rings.
10. Loosen tube nut (Figure 7, Item 9) and remove line (Figure 7, Item 10) from fitting (Figure 7, Item 8). Position
line aside.
11. Remove fitting (Figure 7, Item 8) from filter base (Figure 7, Item 1).
12. Remove two O-rings (Figure 7, Item 7) from fitting (Figure 7, Item 8). Discard O-rings.
13. Loosen water separator (Figure 7, Item 16) from filter (Figure 7, Item 11).
14. Loosen filter (Figure 7, Item 11) from filter base (Figure 7, Item 1).
15. Remove two bolts (Figure 7, Item 6), washers (Figure 7, Item 5) and filter base (Figure 7, Item 1) from bracket
(Figure 7, Item 2).
16. Remove seven bolts (Figure 7, Item 3), washers (Figure 7, Item 4) and bracket (Figure 7, Item 2) from
machine.
Figure 7. Filter and Base.
0071