TM 5-2410-241-23-2
0071
FILTER BASE AND MOUNTING PLATE REMOVAL CONTINUED
17. Remove filter (Figure 8, Item 9), O-ring (Figure 8, Item 8) and water separator (Figure 8, Item 11) from filter
base (Figure 8, Item 5). Discard O-ring.
18. Remove water separator (Figure 8, Item 11) and O-ring (Figure 8, Item 10) from filter (Figure 8, Item 9).
Discard O-ring.
N OT E
Note size and position of bolts to aid installation.
19. Remove two bolts (Figure 8, Item 2), washers (Figure 8, Item 3), prime pump (Figure 8, Item 1) and gasket
(Figure 8, Item 4) from filter base (Figure 8, Item 5). Discard gasket.
20. Remove four plugs (Figure 8, Item 6) and O-rings (Figure 8, Item 7) from filter base (Figure 8, Item 5). Discard
O-rings.
Figure 8. Prime Pump.
0071
END OF TASK
CLEANING AND INSPECTION
00071
Clean and inspect all parts IAW Mechanical General Maintenance Instructions (WP 0295).
END OF TASK