AIR CLEANER ASSEMBLY SERVICE
Figure 2. Air Filters Elements.

Field Maintenance Manual D7R Dozer Type I With Winch and Type II With Ripper
Page Navigation
  503    504    505    506    507  508  509    510    511    512    513  
img
.
TM 5-2410-241-23-2
0111
WARN I N G
If CBRN exposure is suspected, personnel wearing protective equipment should handle all
air cleaner media. Consult your CBRN Officer NCO for appropriate handling or disposal
procedures.
Refer to FM 3-11.3, Multiservice Tactics, Techniques, and Procedures for Chemical,
Biological, Radiological, and Nuclear Contamination Avoidance and FM 3-11.5,
Multiservice Tactics, Techniques, and Procedures for Chemical, Biological, Radiological,
and Nuclear Decontamination.
Allow engine to cool off before performing maintenance on air cleaner. Hot metal parts can
cause severe burns. Wear eye, hand, and skin protection when working with heated parts.
Failure to follow these warnings may cause injury or death to personnel.
AIR CLEANER ELEMENTS REMOVAL
000111
1. Open left side access door (TM 5-2410-241-10).
2. Open clips (Figure 1, Item 3) and remove cover (Figure 1, Item 1) from housing (Figure 1, Item 2).