AIR CLEANER ASSEMBLY REMOVAL CONTINUED
12. Open clips (Figure 7, Item 6) and remove cover (Figure 7, Item 2) from housing (Figure 7, Item 1).
13. Remove seal (Figure 7, Item 3) from cover (Figure 7, Item 2). Discard seal.
14. Remove primary filter element (Figure 7, Item 4) and secondary filter element (Figure 7, Item 5) from housing
(Figure 7, Item 1).
Figure 7. Air Cleaner Housing and Elements.