Figure 8. Air Cleaner Housing Bracket.
Figure 10. Air Cleaner Housing.

Field Maintenance Manual D7R Dozer Type I With Winch and Type II With Ripper
Page Navigation
  510    511    512    513    514  515  516    517    518    519    520  
img
. . .
TM 5-2410-241-23-2
0111
AIR CLEANER HOUSING BRACKET INSTALLATION
000111
1. Install plate (Figure 8, Item 5), two washers (Figure 8, Item 7) and bolts (Figure 8, Item 6) on machine.
2. Install plate (Figure 8, Item 4), seven washers (Figure 8, Item 8) and bolts (Figure 8, Item 9) on machine.
3. Install plate (Figure 8, Item 1), eight washers (Figure 8, Item 3) and bolts (Figure 8, Item 2) on machine.
4. Install air cleaner housing (in this work package).
5. Install primary fuel filter and base (WP 0071).
6. Install water temperature regulator outlet pipe (WP 0051).
7. Install A/C compressor bracket (WP 0097).
8. Install muffler bracket (WP 0045).
END OF TASK
AIR CLEANER ASSEMBLY INSTALLATION
000111
1. Install secondary filter element (Figure 9, Item 5) and primary filter element (Figure 9, Item 4) on housing
(Figure 9, Item 1).
2. Install new seal (Figure 9, Item 3) on cover (Figure 9, Item 2).
3. Install cover (Figure 9, Item 2) and clips (Figure 9, Item 6) on housing (Figure 9, Item 1).
Figure 9. Air Cleaner Housing and Elements.
0111