TM 5-2410-241-23-2
0111
AIR CLEANER HOUSING BRACKET REMOVAL
000111
1. Remove muffler bracket (WP 0045).
3. Remove water temperature regulator outlet pipe removed (WP 0051).
5. Remove air cleaner housing (in this work package).
6. Remove eight bolts (Figure 8, Item 2), washers (Figure 8, Item 3), and plate (Figure 8, Item 1) from machine.
7. Remove seven bolts (Figure 8, Item 9), washers (Figure 8, Item 8), and plate (Figure 8, Item 4) from machine.
8. Remove two bolts (Figure 8, Item 6), washers (Figure 8, Item 7), and plate (Figure 8, Item 5) from machine.
Figure 8. Air Cleaner Housing Bracket.
0111
END OF TASK
CLEANING AND INSPECTION
000111
Clean and inspect all parts IAW Mechanical General Maintenance Instructions (WP 0295).
END OF TASK