TM 5-2410-241-23-2
0154
FRONT FLOOD LAMP HARNESS REMOVAL CONTINUED
N OT E
Tag and mark electrical connectors to aid installation.
Note harness routing to aid installation
Mark location and number of tiedown straps before removal.
2. Remove tiedown strap (Figure 2, Item 5) from connector (Figure 2, Item 6). Discard tiedown strap.
3. Disconnect connector (Figure 2, Item 4) from connector (Figure 2, Item 6).
4. Remove tiedown strap (Figure 2, Item 3) and grommet (Figure 2, Item 1) from radiator guard (Figure 2, Item 7).
Discard tiedown strap.
5. Remove grommet (Figure 2, Item 1) from harness (Figure 2, Item 2).
6. Position harness (Figure 2, Item 2) and connector (Figure 2, Item 4) from inside of radiator guard (Figure 2,
Item 7).
Figure 2. Front Connector.
0154