FRONT FLOOD LAMP HARNESS INSTALLATION CONTINUED
N OT E
Install electrical connectors as noted during removal.
Install harness as noted during removal.
Install tiedown straps as noted during removal.
3. Position connector (Figure 9, Item 3) and harness (Figure 9, Item 6) on bracket (Figure 9, Item 1).
4. Install grommet (Figure 9, Item 2) on harness (Figure 9, Item 6).
5. Install grommet (Figure 9, Item 2) on bracket (Figure 9, Item 1).
6. Connect connector (Figure 9, Item 3) on light (Figure 9, Item 4).
7. Install new tiedown straps (Figure 9, Item 5) on harness (Figure 9, Item 6).
Figure 9. Front Flood Lamp.