FRONT FLOOD LAMP HARNESS INSTALLATION CONTINUED
N OT E
Install electrical connectors as noted during removal.
Install harness as noted during removal.
8. Position connector (Figure 10, Item 4) and harness (Figure 10, Item 2) on inside radiator guard (Figure 10,
Item 7).
9. Install grommet (Figure 10, Item 1) on harness (Figure 10, Item 2).
10. Install grommet (Figure 10, Item 1) and new tiedown strap (Figure 10, Item 3) on radiator guard (Figure 10,
Item 7).
11. Connect connector (Figure 10, Item 4) on connector (Figure 10, Item 6).
12. Install new tiedown strap (Figure 10, Item 5) on connector (Figure 10, Item 6).
Figure 10. Front Connector.