BACKUP ALARM HARNESS REPLACEMENT
Figure 4. Alarm Harness.

Field Maintenance Manual D7R Dozer Type I With Winch and Type II With Ripper
Page Navigation
  938    939    940    941    942  943  944    945    946    947    948  
img
.
TM 5-2410-241-23-2
0168
REMOVAL CONTINUED
4. Remove three bolts (Figure 2, Item 1), washers (Figure 2, Item 2), and cover (Figure 2, Item 3) from machine.
Figure 2. Cover.
0168
N OT E
Tag and mark electrical connectors to aid installation.
Note harness routing to aid installation.
5. Remove tiedown strap (Figure 3, Item 2) from connector (Figure 3, Item 3). Discard tiedown strap.
6. Disconnect connector (Figure 3, Item 1) from connector (Figure 3, Item 3).
Figure 3. Alarm Connector.
0168
0168-2