HYDRAULIC OIL COOLER LINES REPLACEMENT
Figure 1. Upper Hydraulic Oil Cooler Line Elbow.

Field Maintenance Manual D7R Dozer Type I With Winch and Type II With Ripper
Page Navigation
  1123    1124    1125    1126    1127  1128  1129    1130    1131    1132    1133  
img
TM 5-2410-241-23-2
0189
UPPER HYDRAULIC OIL COOLER LINE REMOVAL
000189
WARN I N G
DO NOT disconnect or remove any hydraulic system hoses, tubes, or fittings unless
engine is shut down and hydraulic system pressure has been relieved. Tighten all
connections before applying pressure. Escaping hydraulic fluid under pressure can
penetrate skin.
At operating temperature, hydraulic oil is hot. Allow hydraulic oil to cool before removing
any hydraulic fitting.
To prevent injury to personnel, wear protective eye covering and gloves.
Failure to follow these warnings may result in injury or death to personnel.
C AU T I O N
Cap all hydraulic hose and tube ends along with component connections during removal
to protect against contamination. Failure to follow this caution may cause damage to
equipment.
N OT E
Tag all hoses, tubes, and fittings to aid installation.
Use a container to catch any fluid that maydrain from hoses or system. Dispose of fluid
IAW local policy and ordinances. Ensure all spills are cleaned up.
Note routing of hoses and lines to aid installation.
0189-2