Figure 4. Bulb Assembly.
Figure 6. Lamp Connectors.

Field Maintenance Manual 3 D7R Dozer Type I With Winch and Type II With Ripper
Page Navigation
  617    618    619    620    621  622  623    624    625    626    627  
img
.
TM 5-2410-241-23-3
0252
ASSEMBLY
000252
C AU T I O N
Do not touch the glass surface of a halogen bulb with bare fingers, as the surface will be
exposed to the salts and oils in the hand. If glass is touched, it must be cleaned
immediately with a gentle solvent such as alcohol. Failure to follow this caution will result
in early bulb failure.
1. Install new bulb (Figure 5, Item 2) into lamp assembly (Figure 5, Item 1), feeding the bulb white wire under the
plastic retainer (Figure 5, Item 3).
2. Secure bulb in place by engaging bale wires (Figure 5, Item 4) under lugs (Figure 5, Item 5).