TM 5-2410-241-23-3
0252
REMOVAL
000252
N OT E
Tag electrical connector to aid installation.
The following procedure is for the right side cab flood lamps. Use the same procedure for
the left side cab flood lamps.
1. Disconnect electrical connector (Figure 1, Item 13).
2. Remove bolt (Figure 1, Item 3), washer (Figure 1, Item 2), and flood lamp (Figure 1, Item 7) from guard
(Figure 1, Item 8).
3. Remove nut (Figure 1, Item 1), two washers (Figure 1, Item 6), bolt (Figure 1, Item 5), and bracket (Figure 1,
Item 4) from flood lamp (Figure 1, Item 7).
4. Repeat Steps 1-3 for other light.
N OT E
Only perform steps 5 though 7 if guard will be removed from machine.
r
Tag wiring harness to aid installation.
5. Remove tiedown straps (Figure 1, Item 11) and position wiring harness (Figure 1, Item 9) aside. Discard
tiedown straps.
0252-2