PREPARE FOR TEST
Table 1. Arctic Kit Troubleshooting Procedures for the D7R Dozer.

Field Maintenance Manual 3 D7R Dozer Type I With Winch and Type II With Ripper
Page Navigation
  891    892    893    894    895  896  897    898    899    900    901  
img
. .
TM 5-2410-241-23-3
0285
MEASURING FUEL FLOW
000285
Figure 1. Measuring Fuel Flow.
0285
1. Place fuel pressure line (Figure 1, Item 2) from metering pump (Figure 1, Item 1) into 25 mL measuring
cylinder (Figure 1, Item 4).
2. Switch arctic heater (Figure 1, Item 3) ON (TM 5-2410-241-10) and wait until metering pump (Figure 1, Item 1)
starts pumping fuel.
3. Hold measuring cylinder (Figure 1, Item 4) at level of arctic heater (Figure 1, Item 3) for duration of test.
N OT E
Metering pump will automatically stop pumping fuel after 68 seconds.
4. Once metering pump (Figure 1, Item 1) stops pumping fuel, switch arctic heater (Figure 1, Item 3) OFF (TM 5-
2410-241-10).
5. Replace fuel metering pump (Figure 1, Item 1) (WP 0293) if fuel level in metering cylinder (Figure 1, Item 4) is:
a. above 8.25 mL or,
b. below 6.75 mL,
6. Once measurement is completed, reconnect fuel pressure line (Figure 1, Item 2) to arctic heater (Figure 1,
Item 3).
7. Return to Arctic Kit Troubleshooting.
END OF TASK
END OF WORK PACKAGE
0285-3/(4 blank)