TM 5-2410-241-23-3
0286
Table 1. Arctic Kit Troubleshooting Procedures for the D7R Dozer - Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
2. ARCTIC HEATER TURNS ON
Arctic Heater Fresh Air Tube
3. Inspect arctic heater fresh
AND SHUTS DOWN CON-
Kinked, Bent, or Damaged -
air intake tube (Figure 2,
TINUED.
Item 1) and port for kinks,
Replace arctic heater fresh air
bends, damage, and
restrictions.
Arctic Heater Fresh Air Intake
Tube Restricted - Clear restriction
from arctic heater fresh air intake
tube.
Arctic Heater Turns On and
4. Turn arctic heater switch
Shuts Down - Replace the arctic
ON (TM 5-2410-241-10)
and verify arctic fuel meter-
ing pump is activated.
Arctic Heater Fuel Metering
Pump will run when switch
Pump Turns ON - Perform Arctic
is activated and arctic
heater determines the tem-
perature is OK for arctic
heater operation.
3. ARCTIC HEATER DOES NOT
Test 1 - Inspect Fuse.
TURN ON
1. Turn battery disconnect
switch and ignition switch to
the OFF position (TM 5-
2410-241-10).
Fuse Open - Proceed to Test 3.
2. Inspect the Auxiliary PWR
Unswitched 15a fuse (TM
Fuse OK - Proceed to Test 2.
5-2410-241-10).
Test 2 - Test Arctic Heater
Power, Ground, and Signal.
1. Disconnect harness con-
nector B2 (WP 0018, Fig-
ure 18) from arctic heater
(WP 0018, Figure 18).
2. Turn battery disconnect
switch and ignition switch to
the ON position (TM 5-
2410-241-10).
3. Turn arctic heater switch to
the ON position (TM 5-
2410-241-10).
Voltage OK - Proceed to next step.
test for voltage between
Voltage Not OK - Proceed to
harness connector B2 ter-
Test 4.
minal A3 (WP 0018, Figure
18) and machine ground.
Voltage should be between 18-
26 Volts.