• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
Figure 14. Upper Right Access Panel.
Figure 2. Arctic Kit Heater.

Field Maintenance Manual 3 D7R Dozer Type I With Winch and Type II With Ripper
Page Navigation
  946    947    948    949    950  951  952    953    954    955    956  
img
. . . . . . . .
10
TM 5-2410-241-23-3
0291
FIELD MAINTENANCE
-
ARCTIC KIT HEATER AND BRACKET REPLACEMENT
02
91
Removal, Cleaning and Inspection, Installation
INITIAL SETUP
Equipment Condition
Tools and Special Tools
0
0
Tool Kit, General Mechanic's
Machine parked (TM 5-2410-241-10)
0
(WP 0302, Item 65)
Cooling system drained (WP 0113)
0
0
Ether bottle, valve, and bracket removed
Materials/Parts
0
(WP 0060)
0
Cap Set, Protective (WP 0303, Item 4)
0
Personnel Required
Rag, Wiping (WP 0303, Item 24)
0
0
Tag, Marker (WP 0303, Item 34)
Two
0
0
O-ring
Drawing Required
0
0
References
TM 5-2410-241-24P, Figure 152
0
0
WP 0295
Estimated Time to Complete
0
0
4.5 Hr
0
REMOVAL
000291
1. Turn fuel valve (Figure 1, Item 1) to OFF position.
Figure 1. Arctic Kit Heater Fuel Shutoff.
0291
0291-1


Privacy Statement