TM 5-2410-241-23-3
0288
REMOVAL CONTINUED
13. Remove two nuts (Figure 5, Item 3), washers (Figure 5, Item 4), and battery hold down (Figure 5, Item 1) from
batteries (Figure 5, Item 2).
Use assistance and appropriate lifting device when removing battery. Failure to follow this
warning may result in injury or death to personnel.
N OT E
Each battery weighs approximately 121 lb (55 kg).
Note position of batteries to aid installation.
14. Install lifting device on arctic kit batteries (Figure 5, Item 2).
15. Using lifting device, remove two arctic kit batteries (Figure 5, Item 2) from arctic kit battery box (Figure 5,
Item 5).
16. Remove lifting device from arctic kit batteries (Figure 5, Item 2).
Figure 5. Arctic Kit Batteries.
0288
END OF TASK
CLEANING AND INSPECTION
000288
Clean and inspect all parts IAW Mechanical General Maintenance Instructions (WP 0295).
END OF TASK