Figure 2. Floodlamp Wiring Harness and Connector.
Figure 4. Quick Drop Valve Guard.

Field Maintenance Manual 3 D7R Dozer Type I With Winch and Type II With Ripper
Page Navigation
  1006    1007    1008    1009    1010  1011  1012    1013    1014    1015    1016  
img
.
TM 5-2410-241-23-3
0297
LIFT CYLINDER REMOVAL CONTINUED
4. Remove nut (Figure 3, Item 3), washer (Figure 3, Item 4), bolt (Figure 3, Item 2), washer (Figure 3, Item 1),
P-clip (Figure 3, Item 5), and clamp (Figure 3, Item 6) from fluid tube (Figure 3, Item 7).
5. Using a tiedown strap, bundle and secure wiring harness to retention clip (Figure 3, Item 8).
6. Repeat steps 1 through 5 on other side of machine.
Figure 3. Footlight Wiring Harness.
0297
0297-7