TM 5-2410-240-10
0004
OPERATOR CONTROLS AND INDICATORS CONTINUED
Battery Disconnect Switch and Emergency Disconnect Switch
0004
Figure 17. Battery Disconnect Switch and Emergency Shutoff Switch.
0004
KEY
COMPONENT
DESCRIPTION
1
Emergency Shutoff Switch
Used to shut off engine in the event of an electrical
malfunction. Open red cover, move switch up to shut off
engine. DO NOT operate machine until malfunction has been
corrected. Notify Field Maintenance.
2
Battery Disconnect Switch
Disconnects batteries from rest of machine. Includes a
mechanical lockout cover to prevent unwanted access to
switch.
Insert disconnect switch key and turn switch clockwise to the
ON position to activate machine electrical system and enable
engine start.
Insert key and turn switch counterclockwise to the OFF
position to deactivate machine electrical system or to shut
down engine if it must be stopped quickly.