16
TM 5-2410-240-10
OPERATOR MAINTENANCE
-
OPERATION UNDER USUAL CONDITIONS
000
5
Scope; Initial Adjustment Before Use; Mounting and Dismounting; Seat, Seat Belt, and Control
Adjustments; Engine Starting and Machine Warm-up; Parking; Digital Display Window: Messenger
Display; Operational Information; Transmission and Steering Control; Winch Operation
INITIAL SETUP
References
0
0
0
0
SCOPE
0005
This work package provides instructions on operating the D6K Dozer under usual conditions. Refer to WP 0006 for
operating instructions under unusual conditions. Before, during, and after operation, perform applicable Operator
Preventive Maintenance Checks and Services (PMCS) (WP 0012).
INITIAL ADJUSTMENT BEFORE USE
0005
Perform all Before Operator PMCS checks and services (WP 0012).
Turn battery disconnect switch to ON position (WP 0004).
MOUNTING AND DISMOUNTING
0005
WARN I N G
Mount and dismount the machine only atlocations that have steps and hand holds.
Clean steps and hand holds prior to mounting machine.
Face machine during mounting and dismounting.
Maintain three-point contact (two hands and one foot, or one hand and two feet) at all
times.
DO NOT use angle cylinders as a step.
DO NOT mount or dismount a moving machine.
DO NOT jump off a moving machine.
DO NOT carry tools or supplies when mounting or dismounting machine.
DO NOT use any controls as hand hods during mounting or dismounting.
l
Failure to follow these warnings may result in injury or death to personnel.
1. Open left door.
2. Enter machine from left side and occupy operator's seat.
3. Close left door.
END OF TASK