Figure 18. Fuel Filter/Water Separator.
Figure 19. Cab Fresh Air Filter and Hydraulic Tank Filler Cap.

Operator Manual D6K Dozer Type I With Winch and Type II With Ripper
Page Navigation
  119    120    121    122    123  124  125    126    127    128    129  
img
.
TM 5-2410-240-10
0012
Table 1. Preventive Maintenance Checks and Services (PMCS) - Continued
LOCATION
ITEM TO BE
CHECKED
OR
EQUIPMENT NOT
ITEM
MAN-
SERVICED
PROCEDURE
READY/AVAILABLE IF:
NO.
INTERVAL HOURS
46
After
Cab Fresh Air
WARN I N G
Filter
If CBRN exposure is suspeced, personnel wearing pro-
t
tective equipment should handle all air cleaner media.
Consult your CBRN Officer or CBRN NCO for appropriate
handling or disposal procedures.
In the event of CBRN contamination, see FM 3-11.5,Multi-
service Tactics, Techniques, and Procedures for Chemi-
cal, Biological, Radiological, and Nuclear
Decontamination.
CBRN-contaminated filters must be handled using ade-
quate precautions and must be disposed of by trained per-
sonnel.
Failure to follow these warnin s may cause injury or death
g
to personnel.
C AU T I O N
Do not wash filter while it is installed on machine. Damage
to machine may result.
N OT E
Filter may be cleaned with a solution of warm water and
Detergent, general purpose, liquid (WP 0022, Item 4).
Thoroughly rinse filter in clean water and dry completely
using compressed air prior to installing filter.