TM 5-2410-240-10
0012
Table 1. Preventive Maintenance Checks and Services (PMCS) - Continued
LOCATION
ITEM TO BE
CHECKED
OR
EQUIPMENT NOT
ITEM
MAN-
SERVICED
PROCEDURE
READY/AVAILABLE IF:
NO.
INTERVAL HOURS
45
After
0.2
Fuel System
WARN I N G
Primary Filter/
Water
Separator
Drain
DO NOT smoke or permit any open flame in area of
machine while you are servicing fuel system.
Operating personnel must wearfuel-resistant gloves when
handling fuels. If exposed to fuel, promptly wash exposed
skin and change fuel-soaked clothing.
Failure to follow these warnin s may cause injury or death
g
to personnel or damage to equipment.
N OT E
Place portable fire extinguisher within reach prior to ser-
vicing fuel system.
a. Open cover from left engine
Any fuel leak is evident.
enclosure panel.
b. Open drain valve and allow
water and sediment to drain into
suitable container.
c. Close drain valve.
d. Install cover.
e. Close left front access door.
Figure 18.
0012