Figure 24. Hydraulic Tank Sight Gauge - Type II with Ripper.
Figure 26. Window Washer Fluid Tank.

Operator Manual D6K Dozer Type I With Winch and Type II With Ripper
Page Navigation
  127    128    129    130    131  132  133    134    135    136    137  
img
.
TM 5-2410-240-10
0012
Table 1. Preventive Maintenance Checks and Services (PMCS) - Continued
LOCATION
ITEM TO BE
CHECKED
OR
EQUIPMENT NOT
ITEM
MAN-
SERVICED
PROCEDURE
READY/AVAILABLE IF:
NO.
INTERVAL HOURS
RIGHT SIDE
55
After
Overall View
Check right side of machine for
Damaged components or
evidence of leakage or damage.
Class III leaks.
56
After
Batteries
a. Remove right rear access
cover.
b. Check batteries and battery
Batteries or battery
holddown missing or
holddown for damaged or missing
damaged.
parts.
c. Check for loose battery cables.
Cables are loose, missing,
or damaged.
d. Check for damaged or missing
battery cable grommets.
Figure 25.
Batteries.