Figure 29. Winch Oil Level and Fill Plugs.
CHAPTER 5 MAINTENANCE INSTRUCTIONS

Operator Manual D6K Dozer Type I With Winch and Type II With Ripper
Page Navigation
  133    134    135    136    137  138  139    140    141    142    143  
img
TM 5-2410-240-10
0012
Table 1. Preventive Maintenance Checks and Services (PMCS) - Continued
LOCATION
ITEM TO BE
CHECKED
OR
EQUIPMENT NOT
ITEM
MAN-
SERVICED
PROCEDURE
READY/AVAILABLE IF:
NO.
INTERVAL HOURS
64
Every 500
Fuel Tank
a. Remove fuel tank filler cap and
Filler cap or strainer
Service
Filler Cap
strainer.
damaged or missing.
Hours or 1
Filter and
b. Clean strainer using cleaning
Year
Strainer
compound, solvent, Type III. Air
dry, then reinstall strainer.
c. Disassemble filler cap.
d. Clean dirt and debris.
e. Inspect seal and boot. Replace
if damaged.
f. Reassemble filler cap and
install.
65
Every
Rollover
Check ROPS for damage and
Loose or missing ROPS
1,000
Protective
loose or missing mounting bolts.
bolts or damage to
Service
Structure
structure.
Hours or 6
(ROPS)
Months