Table 2. Powertrain and Chassis Troubleshooting with Codes - Continued.
Table 2. Powertrain and Chassis Troubleshooting with Codes - Continued.

Field Maintenance Manual 1 D6K Dozer Type I With Winch and Type II With Ripper
Page Navigation
  495    496    497    498    499  500  501    502    503    504    505  
img
. . . . . . . .
TM 5-2410-240-23-1
0020
Table 2. Powertrain and Chassis Troubleshooting with Codes - Continued.
CID FMI CODE
Test or Inspection
Corrective Action
0444-03 Starter Motor Relay
8. Using digital multimeter (WP
Continuity - Proceed to step 9.
Voltage Above Normal -
0283), test for continuity between
No Continuity - Replace platform wir-
Continued
pin 28 on platform harness to
ing harness (WP 0150, WP 0155).
engine harness connector PL-
Ensure all harness connectors are
C15 (WP 0018, Figure 225) and
reconnected. Verify proper operation
pin 7 on platform harness ECM J2
of machine (TM 5-2410-240-10).
connector PL-C5 (WP 0018, Fig-
ure 218).
9. Using digital multimeter (WP
No Continuity - Proceed to step 10.
0283), test for continuity between
Continuity - Replace platform wiring
pin 7 on platform harness ECM J2
harness (WP 0150, WP 0155).
connector PL-C5 (WP 0018, Fig-
Ensure all harness connectors are
ure 218) and all other pins on plat-
reconnected. Verify proper operation
form harness ECM J2 connector
of machine (TM 5-2410-240-10).
PL-C5 (WP 0018, Figure 218).
10. Disconnect platform harness
ECM J1 connector PL-C4 (WP
0018, Figure 217) from machine
ECM (WP 0147, WP 0149).
11. Using digital multimeter (WP
No Continuity - Replace machine
0283), test for continuity between
ECM (WP 0147, WP 0149). Ensure all
pin 7 on platform harness ECM J2
harness connectors are reconnected.
connector PL-C5 (WP 0018, Fig-
Verify proper operation of machine
ure 218) and all other pins on plat-
(TM 5-2410-240-10).
form harness ECM J1 connector
Continuity - Replace platform wiring
PL-C4 (WP 0018, Figure 217).
harness (WP 0150, WP 0155).
Ensure all harness connectors are
reconnected. Verify proper operation
of machine (TM 5-2410-240-10).