TM 5-2410-240-23-1
0020
Table 2. Powertrain and Chassis Troubleshooting with Codes - Continued.
CID FMI CODE
Test or Inspection
Corrective Action
N OT E
0444-05 Starter Motor Relay
Current Below Normal
Always inspect harness connectors that are involved in circuit. Poor
connections can often be the cause of an electrical circuit problem.
Verify that all connections in circuit are clean, secure, and connections
are in good condition. If a problem with connection is found, correct
problem and verify diagnostic code is active before performing this
procedure.
Tag wiring harnesses to aid installation.
0444-05 Code Active - Proceed to
machine control ECM and check
step 2.
No Codes Active -The problem does
not exist at this time. Resume normal
operation.
2. Turn ignition switch and battery
disconnect switch to OFF position
(TM 5-2410-240-10).
3. Disconnect engine harness
starter motor connector EN-C2
4. Insert a jumper wire between pins
1 and 2 on engine harness starter
motor connector EN-C2 (WP
5. Check for diagnostic codes (WP
0444-05 Code Active - Proceed to
step 6.
0444-06 Code Active - Replace
starter motor (WP 0095). Ensure all
harness connectors are reconnected.
Verify proper operation of machine
(TM 5-2410-240-10).
6. Turn ignition switch and battery
disconnect switch to OFF position
(TM 5-2410-240-10).
7. Disconnect platform harness to
engine harness connector PL-
engine harness to platform har-
ness connector EN-C15 (WP