TM 5-2410-240-23-1
0020
Table 2. Powertrain and Chassis Troubleshooting with Codes - Continued.
CID FMI CODE
Test or Inspection
Corrective Action
N OT E
0600-03 Hydraulic Oil Temp
Sensor Voltage Above Nor-
Always inspect harness connectors that are involved in circuit. Poor
mal
connections can often be the cause of an electrical circuit problem.
Verify that all connections in circuit are clean, secure, and connections
are in good condition. If a problem with connection is found, correct
problem and verify diagnostic code is active before performing this
procedure.
Tag wiring harnesses to aid installation.
0600-03 Code Active - Proceed to
machine control ECM and check
step 2.
No Codes Active - The problem does
not exist at this time. Resume normal
operation.
2. Turn ignition switch and battery
disconnect switch to OFF position
(TM 5-2410-240-10).
3. Disconnect chassis harness
hydraulic temperature sender
Figure 89) from hydraulic temper-
ature sender (WP 0178).
4. Insert a jumper wire between pins
1 and 2 on chassis harness
hydraulic temperature sender
Figure 89).
5. Check for diagnostic codes (WP
0600-03 Code Active - Proceed to
step 6.
0600-04 Code Active - Replace
hydraulic temperature sensor (WP
0178). Ensure all harness connectors
are reconnected. Verify proper opera-
tion of machine (TM 5-2410-240-10).
6. Disconnect chassis harness to
platform harness connector CH-
platform harness to chassis har-
ness connector PL-C18 (WP