  505    506    507    508    509  510  511    512    513    514    515  
img
. . . . . . . . . . . . .
TM 5-2410-240-23-1
0020
Table 2. Powertrain and Chassis Troubleshooting with Codes - Continued.
CID FMI CODE
Test or Inspection
Corrective Action
0600-04 Hydraulic Oil Temp
14. Using digital multimeter (WP
No Continuity - Replace machine
Sensor Voltage Below Nor-
0283), test for continuity between
ECM (WP 0147, WP 0149). Ensure all
mal - Continued
pin 22 on platform harness ECM
harness connectors are reconnected.
J1 connector PL-C4 (WP 0018,
Verify proper operation of machine
Figure 217) and all other pins on
(TM 5-2410-240-10).
platform harness ECM J2 connec-
Continuity - Replace platform wiring
tor PL-C5 (WP 0018, Figure 218).
harness (WP 0150, WP 0155).
Ensure all harness connectors are
reconnected. Verify proper operation
of machine (TM 5-2410-240-10).
N OT E
0681-03 Parking Brake Sole-
noid Voltage Above Normal
Always inspect harness connectors that are involved in circuit. Poor
connections can often be the cause of an electrical circuit problem.
Verify that all connections in circuit are clean, secure, and connections
are in good condition. If a problem with connection is found, correct
problem and verify diagnostic code is active before performing this
procedure.
Tag wiring harnesses to aid installation.
0681-03 Code Active - Proceed to
1. Connect MSD (WP 0016). Select
step 2.
machine control ECM and check
for diagnostic codes (WP 0013).
No Codes Active - The problem does
not exist at this time. Resume normal
operation.
2. Turn ignition switch and battery
disconnect switch to OFF position
(TM 5-2410-240-10).
3. Disconnect pump harness parking
brake solenoid connector PH-C3
(WP 0018, Figure 207) from park-
ing brake solenoid (WP 0121).
4. Disconnect pump harness to
engine harness connector PH-C1
(WP 0018, Figure 205) from
engine harness to platform har-
ness connector EN-C21 (WP
0018, Figure 137).
5. Using digital multimeter (WP
Continuity - Proceed to step 6.
0283), test for continuity between
No Continuity - Replace pump har-
pin 9 on pump harness to engine
ness (WP 0046). Ensure all harness
harness connector PH-C1 (WP
connectors are reconnected. Verify
0018, Figure 205) and pin 1 on
proper operation of machine (TM 5-
Pump harness parking brake
2410-240-10).
solenoid connector PH-C3 (WP
0018, Figure 207).
0020-62