TM 5-2410-240-23-1
0020
Table 2. Powertrain and Chassis Troubleshooting with Codes - Continued.
CID FMI CODE
Test or Inspection
Corrective Action
0291-05 Engine Cooling Fan 14. Using digital multimeter (WP
0283), test for continuity between
mal - Continued
pin 55 on platform harness ECM
ing harness (WP 0150, WP 0155).
Ensure all harness connectors are
Figure 217) and pin 6 on platform
reconnected. Verify proper operation
harness to engine harness con-
of machine (TM 5-2410-240-10).
232).
No Continuity - Replace machine
0283), test for continuity between
ECM (WP 0147, WP 0149). Ensure all
pin 65 on platform harness ECM
harness connectors are reconnected.
Verify proper operation of machine
Figure 217) and all other pins on
(TM 5-2410-240-10).
platform harness ECM J1 connec-
harness (WP 0150, WP 0155).
Ensure all harness connectors are
reconnected. Verify proper operation
of machine (TM 5-2410-240-10).
N OT E
0291-06 Engine Cooling Fan
Always inspect harness connectors that are involved in circuit. Poor
Normal
connections can often be the cause of an electrical circuit problem.
Verify that all connections in circuit are clean, secure, and connections
are in good condition. If a problem with connection is found, correct
problem and verify diagnostic code is active before performing this
procedure.
Tag wiring harnesses to aid installation.
0291-06 Code Active - Proceed to
machine control ECM and check
step 2.
No Codes Active - The problem does
not exist at this time. Resume normal
operation.
2. Turn ignition switch and battery
disconnect switch to OFF position
(TM 5-2410-240-10).
3. Disconnect engine harness
demand fan solenoid connector
from demand fan solenoid (WP
0199).
4. Check for diagnostic codes (WP
0291-06 Code Active - Proceed to
step 5.
0291-05 Code active - Replace
demand fan solenoid (WP 0199).
Ensure all harness connectors are
reconnected. Verify proper operation
of machine (TM 5-2410-240-10).