TM 5-2410-240-23-1
0020
Table 2. Powertrain and Chassis Troubleshooting with Codes - Continued.
CID FMI CODE
Test or Inspection
Corrective Action
1706-06 Proportional Sole-
No Continuity - Proceed to step 19.
noid Valve (Reverse Right
0283), test for continuity between
Drive Pump) Current Above
pin 52 on platform harness ECM
harness (WP 0150, WP 0155).
Normal - Continued
Ensure all harness connectors are
Figure 217) and all other pins on
reconnected. Verify proper operation
platform harness ECM J1 connec-
of machine (TM 5-2410-240-10).
No Continuity - Replace machine
0283), test for continuity between
ECM (WP 0147, WP 0149). Ensure all
pin 52 on platform harness ECM
harness connectors are reconnected.
Verify proper operation of machine
Figure 217) and all other pins on
(TM 5-2410-240-10).
platform harness ECM J2 connec-
harness (WP 0150, WP 0155).
Ensure all harness connectors are
reconnected. Verify proper operation
of machine (TM 5-2410-240-10).
N OT E
1706-13 Proportional Sole-
noid Valve (Reverse Right
Always inspect harness connectors that are involved in circuit. Poor
Drive Pump) Out of Calibra-
connections can often be the cause of an electrical circuit problem.
tion
Verify that all connections in circuit are clean, secure, and connections
are in good condition. If a problem with connection is found, correct
problem and verify diagnostic code is active before performing this
procedure.
Tag wiring harnesses to aid installation.
1706-13 Code Active - Proceed to
machine control ECM and check
step 2.
No Codes Active - The problem does
not exist at this time. Resume normal
operation.
Perform Hydrostatic Pump and
(reverse right drive pump)