• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
Table 2. Powertrain and Chassis Troubleshooting with Codes - Continued.
Table 2. Powertrain and Chassis Troubleshooting with Codes - Continued.

Field Maintenance Manual 1 D6K Dozer Type I With Winch and Type II With Ripper
Page Navigation
  558    559    560    561    562  563  564    565    566    567    568  
img
. . . . . . . .
TM 5-2410-240-23-1
0020
Table 2. Powertrain and Chassis Troubleshooting with Codes - Continued.
CID FMI CODE
Test or Inspection
Corrective Action
1706-06 Proportional Sole-
18. Using digital multimeter (WP
No Continuity - Proceed to step 19.
noid Valve (Reverse Right
0283), test for continuity between
Continuity - Replace platform wiring
Drive Pump) Current Above
pin 52 on platform harness ECM
harness (WP 0150, WP 0155).
Normal - Continued
J1 connector PL-C4 (WP 0018,
Ensure all harness connectors are
Figure 217) and all other pins on
reconnected. Verify proper operation
platform harness ECM J1 connec-
of machine (TM 5-2410-240-10).
tor PL-C4 (WP 0018, Figure 217).
19. Using digital multimeter (WP
No Continuity - Replace machine
0283), test for continuity between
ECM (WP 0147, WP 0149). Ensure all
pin 52 on platform harness ECM
harness connectors are reconnected.
J1 connector PL-C4 (WP 0018,
Verify proper operation of machine
Figure 217) and all other pins on
(TM 5-2410-240-10).
platform harness ECM J2 connec-
Continuity - Replace platform wiring
tor PL-C5 (WP 0018, Figure 218).
harness (WP 0150, WP 0155).
Ensure all harness connectors are
reconnected. Verify proper operation
of machine (TM 5-2410-240-10).
N OT E
1706-13 Proportional Sole-
noid Valve (Reverse Right
Always inspect harness connectors that are involved in circuit. Poor
Drive Pump) Out of Calibra-
connections can often be the cause of an electrical circuit problem.
tion
Verify that all connections in circuit are clean, secure, and connections
are in good condition. If a problem with connection is found, correct
problem and verify diagnostic code is active before performing this
procedure.
Tag wiring harnesses to aid installation.
1. Connect MSD (WP 0016). Select
1706-13 Code Active - Proceed to
machine control ECM and check
step 2.
for diagnostic codes (WP 0013).
No Codes Active - The problem does
not exist at this time. Resume normal
operation.
2. Proportional solenoid valve
Perform Hydrostatic Pump and
(reverse right drive pump)
Motor Solenoid Calibration - Refer
requires calibration.
to Calibration (WP 0031).
0020-115


Privacy Statement
Press Release
Contact

© Copyright Integrated Publishing, Inc.. All Rights Reserved.