Table 1. Cab Troubleshooting Without Codes. - Continued.
Figure 34. Lamp Relay Fuse Top Terminal.

Field Maintenance Manual 1 D6K Dozer Type I With Winch and Type II With Ripper
Page Navigation
  682    683    684    685    686  687  688    689    690    691    692  
img
.
TM 5-2410-240-23-1
0021
Table 1. Cab Troubleshooting Without Codes. - Continued.
0021
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
5. All Front and Rear Flood Lamps
4. Using a digital multimeter,
Voltage Within 18 to 26 Volts -
Do Not Work - Continued
measure for voltage (WP
Proceed to Test Step 2.
0283) between lamp relay
Voltage Not Within 18 to 26
fuse bottom terminal B5 (Fig-
Volts - Replace fuse block and
ure 33) and ground.
circuit breaker panel (WP 0201).
Verify proper operation of flood
lamps (TM 5-2410-240-10).
Figure 33. Lamp Relay Fuse Bottom Terminal.
0021
0021-81