Table 1. Cab Troubleshooting Without Codes. - Continued.
Table 1. Cab Troubleshooting Without Codes. - Continued.

Field Maintenance Manual 1 D6K Dozer Type I With Winch and Type II With Ripper
Page Navigation
  686    687    688    689    690  691  692    693    694    695    696  
img
. . . . . . .
TM 5-2410-240-23-1
0021
Table 1. Cab Troubleshooting Without Codes. - Continued.
0021
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
5. All Front and Rear Flood Lamps
5. Using digital multimeter, mea-
Resistance Less Than 5.0 Ohms
Do Not Work - Continued
sure resistance (WP 0283)
- Connect C-C31 (WP 0018,
between C-C30 terminal 5
Figure 28) on flood lamp relay (WP
(WP 0018, Figure 27) and
0018, Figure 55).
ground.
Connect C-C30 (WP 0018, Figure
27) on flood lamp relay #1 (WP
0018, Figure 54).
For D6K Dozer with Ripper, install
ripper operation control handle
(WP 0218). For D6K Dozer with
Winch, install winch operation
control handle (WP 0217).
Install front control panel on right
side console (WP 0217).
Perform troubleshooting procedure
for malfunction Front Flood
Lamp(s) Will Not Work and
malfunction Rear Flood Lamp(s)
Will Not Work in this work
package.
Resistance 5.0 Ohms or Greater
- Proceed to Test Step 6.