Table 1. Cab Troubleshooting Without Codes. - Continued.
0021
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
5. All Front and Rear Flood Lamps
Test Step 8. Test 102-RD Fused
Do Not Work - Continued
Lamp Relay Power Circuit for
Short to Other Circuits in Fuse
Block and Circuit Breaker Panel
Wiring Harness.
1. Remove fuse panel side cover
from machine (TM 5-2410-
240-10).
N OT E
Note location of tiedown straps to aid installation.
2. Remove three tiedown straps
and disconnect harness con-
ure 170) from harness
Figure 30) (WP 0201). Discard
tiedown straps.
for continuity (WP 0283)
Continuity - Replace fuse block
between FP-C5 terminal 1 and
and circuit breaker panel wiring
all other terminals in FP-C5
harness (WP 0201).
Install new lamp relay fuse on fuse
block.
Verify proper operation of flood
lamps (TM 5-2410-240-10).
for continuity (WP 0283)
Step 9.
between FP-C5 terminal 1
Continuity - Replace fuse block
and circuit breaker panel wiring
ground.
harness (WP 0201).
Install new lamp relay fuse on fuse
block.
Verify proper operation of flood
lamps (TM 5-2410-240-10).
0021-89