Table 1. Cab Troubleshooting Without Codes. - Continued.
Figure 35. Ground Point.

Field Maintenance Manual 1 D6K Dozer Type I With Winch and Type II With Ripper
Page Navigation
  687    688    689    690    691  692  693    694    695    696    697  
img
. . . . .
TM 5-2410-240-23-1
0021
Table 1. Cab Troubleshooting Without Codes. - Continued.
0021
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
5. All Front and Rear Flood Lamps
Test Step 6. Inspect Ground
Do Not Work - Continued
Point of Lower Cab Wiring Har-
ness.
Inspect ground point of lower cab
Ground Point or Ring Terminal
wiring harness (Figure 35) for dirt,
Dirty or Corroded - Clean as
corrosion, and damage.
necessary.
Connect C-C31 (WP 0018, Figure
28) on flood lamp relay (WP 0018,
Figure 55).
Connect C-C30 (WP 0018, Figure
27) on flood lamp relay #1 (WP
0018, Figure 54).
For D6K Dozer with Ripper, install
ripper operation control handle
(WP 0218). For D6K Dozer with
Winch, install winch operation
control handle (WP 0217).
Install front control panel on right
side console (WP 0217).
Install fuse panel front cover on
machine (TM 5-2410-240-10).
Verify proper operation of flood
lamps (TM 5-2410-240-10).
Ring Terminal Defective -
Replace lower cab wiring harness
(WP 0228).
Install fuse panel front cover on
machine (TM 5-2410-240-10).
Verify proper operation of flood
lamps (TM 5-2410-240-10).
No Problem Found - Install lower
cab wiring harness terminals on
ground point with mounting
hardware and tighten securely.
Proceed to Test Step 7.
0021-86