• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
Table 1. Cab Troubleshooting Without Codes. - Continued.
Table 1. Cab Troubleshooting Without Codes. - Continued.

Field Maintenance Manual 1 D6K Dozer Type I With Winch and Type II With Ripper
Page Navigation
  695    696    697    698    699  700  701    702    703    704    705  
img
. . . .
TM 5-2410-240-23-1
0021
Table 1. Cab Troubleshooting Without Codes. - Continued.
0021
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
5. All Front and Rear Flood Lamps
Do Not Work - Continued
Figure 36. Lamp Relay Fuse Top Terminal.
0021
Test Step 13. Test for Shorted
Flood Lamp Relay #1 or Shorted
Flood Lamp Switch.
1. Turn LH wiper switch to OFF
position (TM 5-2410-240-10).
2. Turn battery disconnect switch
to OFF position (TM 5-2410-
240-10).
3. Connect harness connector
C-C30 (WP 0018, Figure 27)
on flood lamp relay #1 (WP
0018, Figure 54).
4. Turn battery disconnect switch
to ON position (TM 5-2410-
240-10).
5. Turn LH wiper switch to ON
position (TM 5-2410-240-10).
0021-94