Table 2. Cab Troubleshooting With Codes. - Continued.
Table 2. Cab Troubleshooting With Codes. - Continued.

Field Maintenance Manual 1 D6K Dozer Type I With Winch and Type II With Ripper
Page Navigation
  834    835    836    837    838  839  840    841    842    843    844  
img
. . . . . . . . . .
TM 5-2410-240-23-1
0021
Table 2. Cab Troubleshooting With Codes. - Continued.
0021
CID FMI CODE
TEST OR INSPECTION
CORRECTIVE ACTION
2113-03 Operator In Seat Switch
11. Using digital multimeter, test
No Continuity - Replace lower
Voltage Above Normal - Continued
for continuity (WP 0283)
cab harness (WP 0228). Ensure all
between harness connector
harness connectors are recon-
C-C12 (WP 0018, Figure 22)
nected. Verify proper operation of
terminal 44 and harness con-
machine (TM 5-2410-240-10).
nector C-C24 (WP 0018, Fig-
Continuity - Proceed to step 12.
ure 26) terminal 9.
12. Using digital multimeter, test
No Continuity - Replace lower
for continuity (WP 0283)
cab harness (WP 0228). Ensure all
between harness connector
harness connectors are recon-
C-C12 (WP 0018, Figure 22)
nected. Verify proper operation of
terminal 3 and harness con-
machine (TM 5-2410-240-10).
nector C-C23 (WP 0018, Fig-
Continuity - Proceed to step 13.
ure 25) terminal 2.
13. Disconnect harness connec-
tor PL-C4 (WP 0018, Figure
217) from equipment ECM J1.
14. Disconnect harness connec-
tor PL-C5 (WP 0018, Figure
218) from equipment ECM J2.
15. Using digital multimeter, test
No Continuity - Replace platform
for continuity (WP 0283)
wiring harness (WP 0150,
between harness connector
WP 0155). Ensure all harness con-
PL-C4 (WP 0018, Figure 217)
nectors are reconnected. Verify
terminal 56 and harness con-
proper operation of machine
nector PL-C1 (WP 0018, Fig-
(TM 5-2410-240-10).
ure 214) terminal 44.
Continuity - Proceed to step 16.
16. Using digital multimeter, test
No Continuity - Replace platform
for continuity (WP 0283)
wiring harness (WP 0150,
between harness connector
WP 0155). Ensure all harness con-
PL-C5 (WP 0018, Figure 218)
nectors are reconnected. Verify
terminal 44 and harness con-
proper operation of machine
nector PL-C1 (WP 0018, Fig-
(TM 5-2410-240-10).
ure 214) terminal 3.
Continuity - Proceed to step 17.