Table 2. Cab Troubleshooting With Codes. - Continued.
Table 2. Cab Troubleshooting With Codes. - Continued.

Field Maintenance Manual 1 D6K Dozer Type I With Winch and Type II With Ripper
Page Navigation
  838    839    840    841    842  843  844    845    846    847    848  
img
. . . . . .
TM 5-2410-240-23-1
0021
Table 2. Cab Troubleshooting With Codes. - Continued.
0021
CID FMI CODE
TEST OR INSPECTION
CORRECTIVE ACTION
2113-04 Operator In Seat Switch
19. Using digital multimeter, test
No Continuity - Replace machine
Voltage Below Normal - Continued
for continuity (WP 0283)
ECM (WP 0147, WP 0149).
between harness connector
Ensure all harness connectors are
PL-C5 (WP 0018, Figure 218)
reconnected. Verify proper opera-
terminal 44 and all other termi-
tion of machine (TM 5-2410-240-
nals in harness connector PL-
10).
C5 (WP 0018, Figure 218).
Continuity - Replace platform wir-
ing harness (WP 0150, WP 0155).
Ensure all harness connectors are
reconnected. Verify proper opera-
tion of machine (TM 5-2410-240-
10).
N OT E
2204-03 Auxiliary Lever #1 Position
Sensor Voltage Above Normal
Always inspect harness connectors that are involved in circuit.
Poor connections can often be the cause of an electrical circuit
problem. Verify that all connections in circuit are clean and
secure, and connections are in good condition. If a problem with
connection is found, correct problem and verify diagnostic code
is active before performing this procedure.
Tag wiring harnesses to aid installation.
Perform this test only if condition is active.
1. Turn ignition switch and bat-
tery disconnect switch to OFF
position (TM 5-2410-240-10).
2. Disconnect harness connec-
tor C-C49 (WP 0018, Figure
36) from ripper joystick.
3. Turn battery disconnect switch
and ignition switch to ON posi-
tion (TM 5-2410-240-10).
4. Using digital multimeter, mea-
Voltage Less Than Specified
sure for voltage (WP 0283)
Range - Proceed to step 6.
between harness connector
Voltage Within Specified Range
C-C49 (WP 0018, Figure 36)
- Proceed to step 5.
terminals 1 and 2.
There should be approximately
10 volts 0.5 volts.
5. Using digital multimeter, mea-
Voltage Less Than Specified
sure for voltage (WP 0283)
Range - Proceed to step 6.
between harness connector
Voltage Within Specified Range
C-C49 (WP 0018, Figure 36)
- Replace ripper joystick (WP
terminals 2 and 3.
0218). Ensure all harness connec-
There should be approximately
tors are reconnected. Verify proper
5 volts 0.5 volts.
operation of machine (TM 5-2410-
240-10).
0021-237