Table 2. Cab Troubleshooting With Codes. - Continued.
0021
CID FMI CODE
TEST OR INSPECTION
CORRECTIVE ACTION
2204-03 Auxiliary Lever #1 Position
14. Using digital multimeter, test
No Continuity - Replace platform
Sensor Voltage Above Normal - Con-
for continuity (WP 0283)
wiring harness (WP 0150,
tinued
between harness connector
WP 0155). Ensure all harness con-
PL-C4 (WP 0018, Figure 217)
nectors are reconnected. Verify
terminal 69 and harness con-
proper operation of machine
nector PL-C1 (WP 0018, Fig-
(TM 5-2410-240-10).
ure 214) terminal 45.
Continuity - Proceed to step 15.
15. Using digital multimeter, test
No Continuity - Replace platform
for continuity (WP 0283)
wiring harness (WP 0150,
between harness connector
WP 0155). Ensure all harness con-
PL-C4 (WP 0018, Figure 217)
nectors are reconnected. Verify
terminal 56 and harness con-
proper operation of machine
nector PL-C1 (WP 0018, Fig-
(TM 5-2410-240-10).
ure 214) terminal 44.
Continuity - Proceed to step 16.
16. Using digital multimeter, test
No Continuity - Replace platform
for continuity (WP 0283)
wiring harness (WP 0150,
between harness connector
WP 0155). Ensure all harness con-
PL-C5 (WP 0018, Figure 218)
nectors are reconnected. Verify
terminal 49 and harness con-
proper operation of machine
nector PL-C1 (WP 0018, Fig-
(TM 5-2410-240-10).
ure 214) terminal 70.
Continuity - Proceed to step 17.
17. Using digital multimeter, test
No Continuity - Replace machine
for continuity (WP 0283)
ECM (WP 0147, WP 0149).
between harness connector
Ensure all harness connectors are
PL-C5 (WP 0018, Figure 218)
reconnected. Verify proper opera-
terminal 49 and all other termi-
tion of machine (TM 5-2410-240-
nals in harness connector PL-
10).
C5 (WP 0018, Figure 218).
Continuity - Replace platform wir-
ing harness (WP 0150, WP 0155).
Ensure all harness connectors are
reconnected. Verify proper opera-
tion of machine (TM 5-2410-240-
10).
N OT E
2204-04 Auxiliary Lever #1 Position
Sensor Voltage Below Normal
Always inspect harness connectors that are involved in circuit.
Poor connections can often be the cause of an electrical circuit
problem. Verify that all connections in circuit are clean and
secure, and connections are in good condition. If a problem with
connection is found, correct problem and verify diagnostic code
is active before performing this procedure.
Tag wiring harnesses to aid installation.
Perform this test only if condition is active.
1. Turn ignition switch and bat-
tery disconnect switch to OFF
position (TM 5-2410-240-10).
0021-239